Extraction of Ignitable Liquid Residues by Dynamic ...

Multiple sampling approaches exist; however, activated carbon strip (ACS) static headspace sampling is by far most common in US forensic labs. The ACS method requires 16–24 hours of collection time and ACSs must be eluted with carbon disulfide, known to be highly toxic. Porous layer open tubular (PLOT) dynamic capillary headspace sampling was developed at NIST to collect low-volatility compounds from the headspace …

Headspace Extraction - an overview | ScienceDirect Topics

The adsorbent material is then desorbed by solvent washing or thermal desorption in a manner similar to dynamic headspace analysis. Passive headspace sampling of volatiles is commonly achieved with an activated carbon adsorbent strip (ACS) or a commercially available activated carbon product such as …

Automated headspace solid-phase dynamic extraction to ...

 · PDF 文件technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as “the magic needle”. In SPDE, analytes are concentrated on a 50 m film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5cm) of a 2.5ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace

Dynamic Headspace - 8400 - Dynamic Headspace - …

The Model 8400 is a four-position autosampler for dynamic headspace. The instrument runs in multi-vessel mode, where each vessel is assigned its own time and temperature parameters. Pushing the start key automatically activates a synchronized GC cycle time, so samples that follow do not lay on the trap for a prolonged period. Bake cycles can be delayed. Options include cryofocusing at the GC injection …

Headspace Solid-Phase Dynamic Extraction (SPDE) and GC/MS ...

 · PDF 文件The solid-phase dynamic extraction (SPDE) developed by Chromtech (Idstein, Germany) in 2000 is the first commercially available inside-needle device. It uses coated stainless steel needles (8 cm) with a 50µm film of 20 polydimethylsiloxane (PDMS) and 10 % activated carbon …

Analysis of arson fire debris by low temperature dynamic ...

21/03/2014 · Other headspace sampling methods that are less common include a standard dynamic purge and trap into a cartridge containing activated charcoal or another adsorbent such as p-2,6-diphenylphenyene oxide . We call this a less common method in the present context of fire debris analysis; however, dynamic purge and trap has been one of the classical methods used for headspace …Cited by: 10

US6119534A - Dynamic headspace outgassing system - …

A method and apparatus for collecting outgassed compounds during a dynamic headspace outgassing test includes placing a component to be tested within a sample container formed from an inert material and placing the container within an oven to heat the component. A gas inflow line directs a flow of inert gas to envelop the component within the sample container and mix with the compounds outgassed …Cited by: 15

ASTM E3189 - 19 Standard Practice for Separation of ...

5.3 The principal concepts of static headspace concentration are similar to those of static headspace (Practice E1388) and dynamic headspace concentration (Practice E1413). The static headspace concentration technique can be more sensitive than the static headspace technique and less sensitive than the dynamic. The static techniques do however leave the sample in a condition suitable for resampling, as only a portion, typically less than 10 %, of the headspace …

Binary Mixtures of Chlorobenzene and Cyclohexane Vapours ...

 · PDF 文件activated carbon U-03 at 293 K was examined under static and dynamic conditions. Activated carbon U-03, which corresponds to the product CWS 12X30 of the Chemviron Corporation, was used for immersion calorimetry, studies of the activity coefficient and breakthrough curves, PSAand static adsorption experiments. Adsorption from the vapour phase was studied using gas

Teledyne Tekmar Profile - Environmental Expert

Our world-renowned product lines include Volatile Organic Compound (VOC) systems for Gas Chromatography (GC) Sample Introduction, High-Throughput Purge and Trap sample concentration, Static and Dynamic Headspace analysis, and Sample Automation. The Total Organic Carbon (TOC) and Total Nitrogen (TN) Analyzers provides unparalleled accuracy, precision, throughput and …成立日期: 01/01/1975

Headspace Techniques in Foods, Fragrances and Flavors

 · Activated carbon was effective in reducing both characteristic and malodors within the product container. ... A dynamic headspace gas chromatographic technique was used to quantify 46 volatile ...

Dynamic Headspace - 8400 - Dynamic Headspace - Autosampler ...

The Model 8400 is a four-position autosampler for dynamic headspace. The instrument runs in multi-vessel mode, where each vessel is assigned its own time and temperature parameters. Pushing the start key automatically activates a synchronized GC cycle time, so samples that follow do not lay on the trap for a prolonged period.

Chapter 1 Headspace Sampling: An “Evergreen” Method in ...

Dynamic HS sampling is a non-equilibrium continuous gas extraction process, usually called dynamic headspace analysis or the purge-and-trap method. 15 The D-HS composition provides qualitatively representative samples of the volatile fraction of the investigated matrix, and is characterized by highly flexible sampling conditions and analyte ...

[PDF]Headspace Gas Chromatography as a Green Analytical …

activated carbon or porous polymers are typically used. When thermal desorption is used, Tenax, graphitised carbon black and fluorisil are employed [7,9]. Table 2 provides a look into the recent appli ions of HS-GC for environmental, clinical and food analysis. Preconcentration of analytes in headspace vials Many attempts have been made to ...

Dynamic - Activated Carbon Matrix System by Dynamic Air ...

Dynamic Activated Carbon Matrix systems can be used in: Specialty Appli ions: such as museums, archives, hospitals, labs, manufacturing, embassies. Problem Appli ions: to address issues such as entrainment of kitchen fumes or engine exhaust fumes.; General Appli ions: cleaning the air of gas phase contaminants in commercial buildings or for reduced outdoor air appli ions.

Dynamic headspace outgassing system - Seagate Technology, Inc.

The trap 108 preferably comprises a cylindrical tube which is packed with activated carbon or other similar absorbents that bonds with the outgassed compounds while allowing the inert nitrogen gas to pass harmlessly to the atmosphere. ... The dynamic headspace outgassing system of the present invention provides a number of benefits and ...

Studies about the desorption of volatile halocarbons from ...

 · Studies about the desorption of volatile halocarbons from activated carbon by appli ion of static headspace gas chromatography. Herber U(1), Meisch HU. Author information: (1)Universität des Saarlandes, Zentrum für Umweltforschung, Postfach 15 11 50, D-66041, Saarbrücken, Germany.

Dynamic headspace outgassing system - Seagate Technology LLC

The trap 108 preferably comprises a cylindrical tube which is packed with activated carbon or other similar absorbents that bonds with the outgassed compounds while allowing the inert nitrogen gas to pass harmlessly to the atmosphere. ... The dynamic headspace outgassing system of the present invention provides a number of benefits and ...

ASTM E1413 - 19 - Standard Practice for Separation of ...

ASTM E1412 - 19 Standard Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Passive Headspace Concentration with Activated Charcoal ASTM E1413 - 19 Standard Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration onto an Adsorbent Tube

A Look at Activated Carbon Thermal Regeneration

Typically powdered activated carbon (PAC) is not regenerated, but rather, disposed of, while granular activated carbon (GAC) is regenerated. Regeneration, often referred to as reactivation, is a method of thermally processing the activated carbon to destroy the adsorbed components contained on its surface.

[PDF]7. ANALYTICAL METHODS

A dynamic headspace analyzer and GC/FID with retention indices were employed for the detection of 1,1-dichloro­ ... carbon disulfide Waste water Purge -and -trap (EPA (municipal method 601) with direct ... activated carbon : adsorbent; extract with .

Determining Granular Activated Carbon Adsorption Isotherms ...

 · Determining Granular Activated Carbon Adsorption Isotherms of Benzene as a Volatile Organic Compound May 2000 Water Quality Research Journal of Canada 35(2):219-230

Headspace Measurement of Evaporation Rates of Perfumes ...

Evidently, static and dynamic headspace samplings will give different results, Activated carbon was mainly used until the end of the 1970s, but later discontinued when it was shown that it generated numerous artifacts, especially during thermal resorption. More successful were porous synthetic polymers, such as Porapak and Tenax, especially in ...

[PDF]Centre for Accident Prevention and Occupational Medicine ...

An activated carbon tube is opened and connected to the pump. During working hours the pump and tube are carried by a person or used in a stationary position. For two hours air is drawn through the sampling tube at a flow rate of 10 L/h. The loaded activated carbon is transferred to a 10 mL volumetric flask. 10 mL carbon

Chapter 1 Headspace Sampling: An “Evergreen” Method in ...

Dynamic HS sampling is a non-equilibrium continuous gas extraction process, usually called dynamic headspace analysis or the purge-and-trap method. 15 The D-HS composition provides qualitatively representative samples of the volatile fraction of the investigated matrix, and is characterized by highly flexible sampling conditions and analyte ...

Determining Granular Activated Carbon Adsorption Isotherms ...

May 01, 2000 · Dynamic equilibria between chemical solution, headspace gas and activated carbon were established in the 22-mL headspace glass vials sealed with Teflon-faced silicone septa and aluminum cramp caps. Using the closed system of headspace glass vials minimized the volatilization loss of chemical during the experiment.

[PDF]6. ANALYTICAL METHODS

The headspace method involves equilibrium of volatile analytes such as toluene between a liquid and solid sample phase and the gaseous phase. The gaseous phase is then analyzed by GC. There are two main types of headspace methodology: static (equilibrium) headspace and dynamic headspace which is usually called the "purge and trap" method (Seto ...

Dynamic adsorption of radon by activated carbon

 · The adsorption of radon on activated carbon has been used in or considered for a number of appli ions, including in situ decay beds, cyclic decontamination systems, and diffusive samplers. And although there are numerous measurements of the adsorption coefficients of specific activated …

Dynamic headspace outgassing system - Seagate Technology, Inc.

The trap 108 preferably comprises a cylindrical tube which is packed with activated carbon or other similar absorbents that bonds with the outgassed compounds while allowing the inert nitrogen gas to pass harmlessly to the atmosphere. ... The dynamic headspace outgassing system of the present invention provides a number of benefits and ...

IAQ Solutions - Dynamic Air Quality Solutions / Commercial

Dynamic provides three IAQ Solutions that address all three types of airborne contaminants: Particles; Odors and VOCs; Biological Contaminants; Often, indoor air quality problems are from poor outdoor air quality. Especially in urban areas, ventilation air brought in to meet minimum ventilation air requirements can be contaminated with ultrafine particles (UFPs), odors, exhaust fumes, or a ...

[PDF]An Expedited Approach to the Investigation and Mitigation ...

a. Isotherm and design guidance for activated carbon filters are generally based upon experimentation conducted at 100 ppmV; 4 to 5 orders of magnitude higher than levels of concern at vapor intrusion sites. b. At 3low µg/m levels, the sorption of VOCs appears to be controlled by the diffusive flux of

A Look at Activated Carbon Thermal Regeneration

Prized for its extremely porous surface area, the superior performance of activated carbon as an adsorbent lends itself to a number of appli ions spanning across a range of industries.. One of the major benefits to activated carbon is that it is capable of being d, meaning that “spent” carbon, or carbon saturated with the adsorbed components, can be desorbed of the components to ...

[PDF]Adsorption of CCl4 from Aqueous Solution on Activated …

parameters for the dynamic adsorption of carbon tetrachloride on DTO activated carbon were calculated. INTRODUCTION Increasing requirements for water, linked with limited resources, have compelled changes in water system management. The reconditioning of water allows the re-use of wastewater after its purifica-tion by physicochemical methods.

Dynamic and static removal of benzene from air based on ...

Nov 10, 2020 · Human exposure to high levels of benzene in the air leads to toxic effects in human body and so, it is necessary to determine by high sensitivity and precision methodology. A simple and efficient method based on the triphenyl(3-sulfopropyl)phosphonium p-toluenesulfonate as TSIL was coated on multi-walled carbon nanotubes ([TPhPP][SUTO]–MWCNTs) and used for benzene vapor removal from …

[PDF]METHOD 1312 SYNTHETIC PRECIPITATION LEACHING …

4.3.1 Zero-Headspace Extraction Vessel (ZHE): When the sample ... by passing tap water through a carbon filter bed containing about 500 grams of activated carbon (Calgon Corp., Filtrasorb-300 or equivalent). CD-ROM 1312 - 5 Revision 0 September 1994

Passive headspace extraction of ignitable liquids using ...

 · An activated carbon cloth (ACC) and a commercially available activated carbon strip (ACS) were used to extract a variety of ignitable liquids using passive heated headspace extraction.

Brochures - Dynamic Air Quality Solutions / Commercial

Call Dynamic Air Quality Solutions today where we specialize in commercial air cleaners and air filters for high performance indoor air quality products. ... DYN-236 Activated Carbon Matrix Systems. DYN-236 ACM 1119 LR 4Pg.pdf. Download. Preview. DYN-225 Sterile Sweep UVC System. DYN-225 Sterile Sweep 0620 4pg LR.pdf. Download.

ARID Technologies - Technical Summary

The vapors initially present in the receiving tank are displaced from the headspace by the incoming liquid during the filling process. In the case of vehicle refueling, these "refueling emissions" can be directed back to the storage tank headspace or to an activated carbon canister lo ed on the vehicle.